On arrival system running and cooling as intended and drain lines flowed when flushed. Outdoor units capicator was out of tolerance and compressor was overamping on start up. Added compressor saver kit and changed out customer supplied thermostat. System cooling as I left. Raining at time of maintenance.
Install 36k gas downflow keep current filtration includes code kit
Sold 36k level 2 gas downflow unit 13, 638
Came to house to give quote to aff 80 amp car charger
For this job , I did a super tune up. Everything in the airhandler looked Suggested he get a new filter box and and also showed him the biogrowth and suggested a UV system. At the condenser, SupEr heat and sub cool were in range. In rush was high and capacitor was out of tolerance. Suggested a new capacitor and he installed a hard or soft start. Was told he needs to speak with spouse first. Washed condenser and put everything back together. Air conditioning was running when I left
On arrival system running and cooling producing 20 degrees delta. Drain lines flowing. Indoor unit clean and in good condition. Outdoor unit passed all electrical testing but was overamping on start up. Customer declined all recommendations to address this.
On this job i discovered. The drain line backed up an out of tolernace cap drity blower motor and a bad breaker at the panel that when tured off doesnt turn back on easily. Today im charging for a drian clear in the closet. We talk about membership. He wants a couple of days to think it over. Not interested in system replacement.
On arrival system ran and cooled as intended producing 18 degrees cooling. Indoor unit clean, installed iaq 200 and April aire filter upgrade. Condenser passed all electrical testing. System cooling as I left.
Quoted customer ieq system for home.
4/26/25 Paused job for now the sink customer ordered did not come with mounting brackets. Customer is going to order the mounting brackets and let us know when they come in.
Upon arrival the homeowner informed me that the indoor fan has been running but not blowing cool air. Ownee noticed this happened for the first time 3 weeks ago but has not used the cooling side of the unit since then. Followed the path of 24 volts starting from the outside back to the inside. When arriving to the thermostat,the system began cooling. Jumpered wires y, g, o to r together to keep system running. Checked refrigerant levels and deltas. Everything checked while system was running came back within normal limits. Recommended soft start kit due to over amperage on startup, recommended drain strip due to dirty drain lines, recommended new thermostat due to thermostat being the last thing checked on the 24 v path, recommended membership for discounts and warranties. Owner declined all recommendations at this time and stated they had to talk with their wife before spending mone on anything aside from the evaluation. Left system running on 72 cool.
Customer will pick up sink at have it at the property ready to go on Friday need to schedule for Friday morning install.
On arrival system running and cooling producing 20 degrees of cooling. Indoor unit had bacterial growth but otherwise in good condition. Outdoor unit passed all electrical testing but contactor was buzzing and very pitted. Strongly recommended replacing contactor. System running and cooling on departed.
Arrived onsite valve under sink for cold side of lavatory was off. Went ahead and turned on and everything working great.
Arrived onsite dishwasher is getting g power and going through drain cycle fine not ash cycle though. Am scheduled to come back for additional work wednseday of next week will look at again when I return.